The paper discusses matters relating to furnace construction and operation and those bearing on furnace control. The factors referred to include size and design of gas flues, mains and ports; the size and arrangement of regenerators; infiltration of air; heat transfer in the furnace; the insulation of the furnace crown; design of chimneys; measurement of temperature, pressure, and of the volume and composition of gases.